Product Overview
Ultrasonic flow meters have the characteristics of non clogging, high measurement accuracy, LCD digital display, tensile resistance, zero leakage, and long service life.
Installation position of ultrasonic flowmeter: The selection of installation pipe section has a significant impact on testing accuracy. The selected pipe section should avoid interference and eddy currents, which have a significant impact on measurement accuracy.
Product features
1. Avoid installing machines in areas with strong magnetic fields and vibration interference, such as water pumps, high-power radios, and frequency converters;
2. The selection of pipes should be uniform, dense, and easy to transmit ultrasonic waves; Downstream should be greater than 5D;
3. There should be a sufficiently long straight pipe section, and the upstream straight pipe section of the installation point should be greater than 10D (note: D=diameter),
4. The upstream distance from the installation point to the water pump should be 30D;
5. The fluid should fill the pipeline.